HC 15-95

Condensing Boiler

Excellent value for money, the HC series offers an economical solution to all your home heating needs without sacfificing reliabilty. DHW demand priority standard on all HC models. Pair wih our IBC indirect tanks for a complete system.

· Unique and innovative single pass copper / aluminum heat exchanger, ensuring greater efficiency and eliminating water side corrosion.
· Up to 96% AFUE, with full ASME-rated vessel.
· Built-in boiler pump.
· PVC/CPVC/PPs approved.
· 2” & 3” venting options available.
· Contractor friendly, easy to install, maintain and service.
· Up to 6.25:1 turndown ratio of better load matching.
· Fewer parts ensuring greater reliability.
· Outdoor reset technology increases efficiency by lowering the water temp automatically.
· Reset heating – Set point – DHW.
· Includes air vent, outdoor sensor & relief valve.
· Exceptional value and longevity. Over 1.5 million installed.
· Better reliability and durability.
· 5 Year manufacturer’s parts warranty.
· 10 year limited heat exchanger warranty.

SPECIFICATIONSHC 13-50HC 15-95HC 20-125HC 33-160
CSA Input (Natural Gas or Propane *) – MBH13.5 – 5115 – 9520 – 12533 – 160
CSA Input (Natural Gas or Propane *) – KW3.95 – 14.944.4 – 27.85.6 – 36.69.7 – 46.9
CSA Output – MBH12.4 – 45.414.5 – 85.918.6 – 110.830.4 – 140.0
CSA Output – KW3.64 – 13.34.3 – 25.05.4 – 32.58.9 – 41.0
A.F.U.E95%95%95%94%
Min gas pressure (Nat. Gas or Propane) – inch w.c.5555
Max gas pressure (Nat. Gas or Propane) – inch w.c.14141414
Power (120Vac/60Hz) – Watts @ full fire with internal pump126128130164
Weight (empty) – lbs/Kg84 / 3896 / 4496 / 4496 / 44
Pressure vessel water content – USG/Liters0.37/1.40.37/1.40.5/1.90.5/1.9
Max boiler flow rate – USgpm9101111
Min boiler flow rate – USgpm2233
Max operating pressure – Space Heating Coil – psig43.543.543.543.5
Approved installation altitude – ASL10,000 ft10,000 ft10,000 ft10,000 ft
Ambient temperature – Low (°F/°C)32/032/032/032/0
Ambient temperature – High (°F/°C)122/50122/50122/50122/50
Max relative humidity (non-condensing)90%90%90%90%
Min water temperature – Space Heating (°F/°C)50/1050/1050/1050/10
Max water temperature – Space Heating (°F/°C)194/90194/90194/90194/90
Max equivalent vent length 2″ (each side)35′35’35′35′
Max equivalent vent length 3″ (each side)120′120′120′120′


 
PIPING CONNECTIONS / MEASUREMENTS
 
 
DESCRIPTION DC SERIES BOILERS / WATER HEATERS
 
AExhaust Outlet3″ Schedule 40
BCombustion Air3″ Schedule 40
EHeating Water Inlet (Return)1″ Male NPT
FHeating Water Outlet (Supply)1″ Male NPT
GGas Inlet1/2″ Male NPT
HCondensate Outlet3/4″ Hose
IKnock-out (3)1/2″

MODELHEIGHT
HC 13-5026.6″ [676mm]
HC 15-9529.0″ [736mm]
HC 20-12531.3″ [796mm]
HC 33-16031.3″ [796mm]
TOUCH PANEL CONTROL    
The HC controller functions as an interactive touch-sensitive panel with buttons that light up, showing indicators such as numbers, icons, or letters. Some of these lit indicators signify boiler operational status. Other indicators enable you to program the boiler.